Need help? Contact us

zhonghanghangte@gmail.com
Leave Your Message
CNPVC Lubricant Oil KTP High-Quality Antioxidant Rust Prevention Turbine Oil Kunlun Factory
Turbine Oil

CNPVC Lubricant Oil KTP High-Quality Antioxidant Rust Prevention Turbine Oil Kunlun Factory

CNPVC Lubricant Oil KTP High-Quality Antioxidant Rust Prevention Turbine Oil is suitable for lubrication and sealing of steam turbine units, centrifugal compressors, and blowers in the power industry, refining and chemical industry, steel industry, shipbuilding, and other industrial applications.

    Viscosity Grade and Type

    Product brand: 32、46、68、100

    Specifications and Approvals

    Executive standard:Q/SY RH2088-2012

    Standards met:GB 11120-2011 L-TSA (B)/ L-TSA (A)/ L-TGA

    DIN 51515-1

    Siemens TLV 9013 04Alstom HTGD 90 117 V0001 X

    GE GEK 46506D

    Applications

    Kunlun KTP High-Quality Antioxidant Rust Prevention Turbine Oil is suitable for lubrication and sealing of steam turbine units, centrifugal compressors, and blowers in the power industry, refining and chemical industry, steel industry, shipbuilding, and other industrial applications.

    Application Cases

    Kunlun KTP High-Quality Antioxidant Rust Prevention Turbine Oil is widely used in the thermal power field and occupy a significant market share. The product is used in steam turbine units at enterprises such as Datang Huayuan Power, Honghe Power, Xiamen Gas Power Plant, Chongqing Wansheng Power Plant, Zhongdian Fuxi Power Plant, and Guodian Nanning Power.

    Features

    Feature

    Advantages and potential benefits

    Good viscosity-temperature performance

    Provide basic protection for the turbine

    Good anti-oxidation and anti-rust

    Have long life and prolong oil charge life

    Excellent anti-emulsification

    Ensure rapid separation in contact with water to ensure efficient operation of equipment

    Good air release properties

    Reduce the risk of deposits due to adiabatic compression of air bubbles

    Good anti-foaming properties

    Provide effective oil film protection for good lubrication and heat dissipation

    Typical Data

    Items

    Typical Data

    Testing Methods

    Viscosity Grade

    32

    46

    68

    GB/T3141

    Kinematic Viscosity (40℃), mm2/s

    31.4

    44.3

    67.4

    GB/T265

    Viscosity Index

    106

    110

    99

    GB/T 1995

    Density(20℃), g/cm3

    867.9

    871.6

    875.4

    GB/T 1884

    Flash Point, ℃

    224

    228

    256

    GB/T 267

    Pour Point, ℃

    -15

    -15

    -12

    GB/T 3535

    Total Acid number, mg KOH/g

    0.11

    0.11

    0.11

    GB/T 4945

    Air Release (50℃), min

    2.8

    3.1

    5.2

    SH/T 0308

    Copper Strip Corrosion, 3 h, 100 ℃, Rating

    1a

    1a

    1a

    GB/T 5096

    Rust Characteristics, Procedure B

    Pass

    Pass

    Pass

    GB/T 11143(B)

    Foam Tendency/Stability, ml/ml

    Sequence I(24℃)

    Sequence II(93.5℃)

    Sequence III(24℃)

     

    20/0

    15/0

    20/0

     

    20/0

    15/0

    20/0

     

    20/0

    15/0

    30/0

    GB/T 12579

    Emulsion, Time to 3 ml Emulsion, 54℃, min

    8

    8

    10

    GB/T 7305

    Cleanliness, Grade

    8

    8

    8

    NAS 1638

    Rotating Pressure Vessel Oxidation Test, min,

    >400

    >400

    >400

    SH/T 0193

    Oxidation Stability

    Time for total acid number 2.0 mg KOH/g, h

    >5000

    >5000

    >5000

    GB/T 12581

    Packaging and Storage

    Execute standard NB/SH/T 0164 of packing, mark, transportation, storage and final acceptance.

    200L Packaging, 170±2Kg net.

    Notes

    • The product must be labeled clearly and properly during the entire transportation process to prevent confusion with other kinds of petroleum product.
    • The product must be stored in dedicated storage tanks/equipment and recommended to be stored in an indoor and controlled environment.
    • The storage tank/equipment must be waterproof, moisture-proof, and free from other mechanical particles.
    • All storage equipment, tanks, pipelines, valves, etc. must be thoroughly cleaned and inspected before use to prevent contamination.

    Health and Safety

    • Health and Safety recommendations for this product can be found on the Chemical Material Safety Data Sheet (SDS).

    Leave Your Message